Discontinued App

Linear Calibrator Lite

Linear Calibrator is to be used for a linear data converter such as Celsius to Fahrenheit Converter, and data correction for experimental data. Linear ...

QR Scan this code with your mobile device to download this app

Description

Linear Calibrator is to be used for a linear data converter such as Celsius to Fahrenheit Converter, and data correction for experimental data. Linear Calibrator Lite is a Lite version of the Linear Calibrator software. This can operate the P button up to 3 times. When 10 minutes pass and the software is resumed, the P button can be used again. Suppose that two kinds of data, X and Y, are linear relation and that the data of two points, (X1, Y1) and (X2, Y2), are known. The data of arbitrary point is calculated from the following formulae. Y =(Y2 - Y1)x(X-X1)/(X2 - X1)+ Y1 X =(X2 - X1)x(Y-Y1)/(Y2 - Y1)+ X1 This software is a simple sheet to execute the above calculation. (Example-1) Celsius to Fahrenheit Converter Change 25-degree Centigrade into Fahrenheit. Linear Calibrator solves this in the following three steps. //Step 0: Preparation// Prepare calibration data. They are as follows. P1 0 degC 32 degF P2 100 degC 212 degF //Step 1: Definition// Enter the calibration data into the sheet. NameX = degC, NameY = degF X1 = 0, Y1 = 32 X2 = 100, Y2 = 212 //Step 2: Calculation// Enter 25-degree Centigrade to degC data field. Touch out P button of degC data field. Converted data, 77.0-degree Fahrenheit, is displayed in the degF data field. In case of sequential conversion, DX button can be used. For example, conversions from 30, 35, 40, 45, 50, … are as follows. Increment is 5. Enter 5 in DX text. Touch out the +DX button. Converted data, 86.0 -degree Fahrenheit corresponding to 30 (=20+5) ℃, is displayed in the degF data field. When the +DX button is touched out continuously, the next conversion can be obtained. (Example-2) Data correction for experimental data It is known that the oxygen gas concentration (%) and the oxygen sensor output (mV) have a linear relationship. We have calibrated the oxygen sensor at the following two points. P1 0 % 2 mV P2 21 %21 mV When the oxygen sensor output is 4 mV, how much percent is the exact oxygen gas concentration? //Step 0: Preparation// Prepare calibration data. They are as follows. P1 0 %2 mV P2 21 %21 mV //Step 1: Definition// Enter the calibration data into the sheet. NameX = %, NameY = mV X1 = 0, Y1 = 2 X2 = 21, Y2 = 21 //Step 2: Calculation// Enter data to the mV data field and touch out P button of this field. The 2.21 % of exact gas concentration data is displayed. C button clears data, and enables to calculate next data. [Buttons] //P button// P (put) button inputs data and execute calculation. When the data field is blank, it is interpreted as illegal data. When the data field is illegal character, it is interpreted as zero value. //-DX button// The -DX button subtracts DX value from X value, executes the P button. //+DX button// The +DX button adds DX value to X value, executes the P button. //-DY button// The -DY button subtracts DY value from Y value, executes the P button. //+DY button// The +DY button adds DY value to Y value, executes the P button. //C button// C (Clear) button clears data. [Color change] After the P button execution, data are shown in the following colors. Input data:Blue color Output data:Green color Uncalculated data:Red color The uncalculated data is not output. The former data is remains unchanged in this data field.

More

Technical specifications

Version: 2.02

Size: 72.2 KB

System:

Price: 0,00 €

Day of release: 0000-00-0

Comments about Linear Calibrator Lite

*We won´t use your data for marketing purposes, we only need to check your email

Do you know how to install the app?

Download Linear Calibrator Lite free

Similar apps to Linear Calibrator Lite

We use cookies to improve our services and tailoring our ads to match your requirements and navigation habits. Accept · Read more